【问题标题】:IIB - Creating an integration server on the integration node never completesIIB - 在集成节点上创建集成服务器永远不会完成
【发布时间】:2016-06-15 15:27:20
【问题描述】:

在 Windows 上使用 IBM Integration Bus V10.0.0.3。我在集成工具包中遇到了一个可以在命令行上重现的问题。我可以创建一个新的本地集成节点,但是当我尝试在该节点上创建一个新的集成服务器时,该命令永远不会成功完成。

作为管理员,我要创建节点:

mqsiprofile
mqsicreatebroker NEWNODE
mqsistart NEWNODE

所有这些命令都成功了。然后我尝试创建集成服务器:

mqsicreateexecutiongroup NEWNODE -e SoapIS -w 500 -v D:\log.txt

log.txt 显示如下:

DUMBLEDORE
serializer.version=1.0
commsmessage.type=com.ibm.broker.config.proxy.Request
commsmessage.sessionId=3c38dc7a08a742e6a8a95f7afd2eed8b
...
commsmessage.operationtype=reregister
commsmessage.configobjecttype=<all>

2016-06-15 13:58:39.0371 com.ibm.broker.             { com.ibm.broker.config.proxy.LocalCMPSender.send()
2016-06-15 13:58:39.0371 com.ibm.broker.             } com.ibm.broker.config.proxy.LocalCMPSender.send()
2016-06-15 13:58:39.0371 com.ibm.broker.           } com.ibm.broker.config.proxy.SendManager.send()
2016-06-15 13:58:39.0371 com.ibm.broker.         } com.ibm.broker.config.proxy.AdministeredObjectPool.sendHeartbeatResponse()
2016-06-15 13:58:39.0371 com.ibm.broker.         { com.ibm.broker.config.proxy.AdministeredObjectPool.getLogEntriesFromStringTokenizer()
2016-06-15 13:58:39.0371 com.ibm.broker.         } com.ibm.broker.config.proxy.AdministeredObjectPool.getLogEntriesFromStringTokenizer() retVal=[]
2016-06-15 13:58:39.0371 com.ibm.broker.         { com.ibm.broker.config.proxy.AdministeredObjectPool.findObjectFromResponseElement()
2016-06-15 13:58:39.0371 com.ibm.broker.           d[3]: affectedConfigObjectType=<unknown>,affectedUUID=null,affectedObjectsParentUUID=null
2016-06-15 13:58:39.0371 com.ibm.broker.           d[3]: referenceParentUUID=null,referenceParentType=null
2016-06-15 13:58:39.0371 com.ibm.broker.         } com.ibm.broker.config.proxy.AdministeredObjectPool.findObjectFromResponseElement() retVal=null
2016-06-15 13:58:39.0371 com.ibm.broker.         d[3]: The actionresponse does not refer to an instantiable object.
2016-06-15 13:58:39.0371 com.ibm.broker.       } com.ibm.broker.config.proxy.AdministeredObjectPool.processResponse()
2016-06-15 13:58:39.0371 com.ibm.broker.     } com.ibm.broker.config.proxy.ReceiveManager.action()
2016-06-15 13:58:39.0371 com.ibm.broker.   } com.ibm.broker.config.proxy.LocalCMPReceiver.deliverMessage()
2016-06-15 13:58:39.0825 main...........   d[2]: AdministeredObjectPool deregistered a thread that is no longer waiting for a 'actionresponse': main
2016-06-15 13:58:39.0825 main...........   d[2]: AdministeredObjectPool registered a waiting for 'actionresponse' thread: main

最后两行重复了很多次。

有人对此有任何见解吗?

【问题讨论】:

    标签: ibm-integration-bus


    【解决方案1】:

    我在 64 位 Windows 上解决了这个问题,

    已通过应用在 Fix Central 2016-05-27 上发布的 IBM Integration Bus 10 修订包 5 进行了修复。我能够创建集成服务器并部署一个 bar 文件没有问题。

    请注意,我还在 Linux X86_64 上测试了 Fix Pack 5,但在 Redhat RHEL 7.2 64-it 上似乎没有解决该问题。