【发布时间】:2014-06-05 18:05:52
【问题描述】:
我正在尝试与作为 OBD-ll ECU 模拟器 (link) 的 ECUsim 2000 进行通信。然而,我总是从设备收到的响应类似于“??”或者 ”?” (当我运行 TouchScan 或 OBD Auto Doctor 等程序时,它们会成功读取数据,因此设备工作正常)。我正在通过 C# 发送命令
serialPort1.Write("010D\r")
我在 SerialPort 的 DataReceived 事件中接收到信号
message = "Data Received: " + serialPort1.ReadExisting();
this.Invoke(new EventHandler(displayText));
我现在没有我所缺少的。这是完整的源代码
private void Form1_Load(object sender, EventArgs e)
{
serialPort1.PortName = "COM3";
serialPort1.BaudRate = 115200;
serialPort1.Parity = System.IO.Ports.Parity.None;
serialPort1.StopBits = System.IO.Ports.StopBits.One;
serialPort1.DataBits = 8;
serialPort1.Handshake = System.IO.Ports.Handshake.None;
serialPort1.Open();
}
private void button1_Click(object sender, EventArgs e)
{
if (serialPort1.IsOpen)
{
serialPort1.Write("010D\r");
}
}
private void displayText(object sender, EventArgs e)
{
textBox1.AppendText(message + "\n");
}
private void serialPort1_DataReceived(object sender, System.IO.Ports.SerialDataReceivedEventArgs e)
{
message = "Data Received: " + serialPort1.ReadExisting();
this.Invoke(new EventHandler(displayText));
}
ECUsim 2000 的默认通讯设置是
波特率:115200 数据位:8 奇偶性:无 停止位:1
协议为 ISO 15765-4,设备上有两个开关,协议属性 CAN ID 29/11 位和 CAN 波特率 500 kbps/250kbps。也许,问题与这些有关,因此没有适当的通信设置。
另一个问题 -> 有没有办法在串行通信中设置协议(如 ISO 15765-4)?
【问题讨论】:
-
那个?字符由 Encoding.ASCII 产生,试图将废话转换回真正的 ASCII 字符并放弃希望,因为数据包含大于 127 的值。没有串行端口设备使用其产品号作为波特率。
-
抱歉,我编辑了代码中显示的波特率。我认为错误是由于解释收到的数据
-
CAN 不使用 ASCII,它不是文本协议。所以不要使用返回字符串的 SerialPort 方法,而是使用 Read()。
标签: c# serial-port obd-ii