【发布时间】:2017-08-25 14:30:12
【问题描述】:
现在我正在开发一个工具,它允许我使用 VB6 和带有以太网屏蔽的 arduino UNO 测量网络连接之间的延迟。 现在我面临一些服务器代码(VB6 程序)的问题。 我有 2 个带有两个不同端口的 winsock,它们都在监听 arduino 客户端进行连接。现在,如果我只有一个活动连接,一切都不会出错,一切正常,但是一旦第二个客户端连接,整个服务器就会开始发疯。突然它报告说第一个连接的客户端失去了连接,所以简而言之,服务器只是不希望一次连接 2 个客户端,但我确实需要它:/ 出了什么问题?
我将快速解释通过 winsock 向服务器发送或从服务器发送的 sertain 命令。
"SERVER_SLEEP" Is a command that the server sends to all clients that will tell them to enter a power saving mode.
"SERVER_REQUESTS_DATA" Is a command that the server sends to a specific client and forces the client to send information like Device name and firmware version.
"RESPOND_MESSAGE" Is a command that the server sends to all clients and the client is forced to respond to see if we still have an connection.
"DEVICE_NAME=" Is a command that the client sends to the server when it just connects, It is required before we show that we have an connection by putting it into the listbox. (after the = comes the device name)
"DEVICE_NAME_REP=" Is a command that the client sends to the server when the server requests information about the client, the reason i have 2 of them is because i couldn't reuse the previous one since then it would become way to complicated. (after the = comes the device name)
"DEVICE_FIRMWARE=" Is a command that the client sends to the server when the server requests information about the client. (after the = comes the device firmware version)
"DEVICE_OK=" Is a command that the client sends to the server when the server requests an answer to check if we still have an connection. (after the = comes the device name)
"DEVICE_REBOOTING" Is a command that the client sends to the server when it goes out of sleep mode (it goes out of that mode when the server comes back online again after it was closed) After the client send that message it immediately closes the connection again and the device is forced to reboot to make sure nothing goes wrong.
我的代码:
Dim DeviceIP1 As String
Dim DeviceIP2 As String
Dim UpdateListStatus As Integer
Private Sub Command1_Click()
MsgBox Socket1.State
MsgBox Socket2.State
End Sub
Private Sub Command3_Click()
If Dir(App.Path & "\TH.exe") <> "" Then 'Traceroute Helper application i wrote before, Works 100% and is not relevant for the issue i am facing
Shell App.Path & "\TH.exe " & DeviceIP, vbNormalFocus
Else
MsgBox "Missing file!" & vbNewLine & "File TH.exe is required for the requested operation!", vbCritical + vbSystemModal, "Missing file"
End If
End Sub
Private Sub Form_Load()
Socket1.Listen
Socket2.Listen
End Sub
Private Sub Form_QueryUnload(Cancel As Integer, UnloadMode As Integer)
Dim msg As VbMsgBoxResult
msg = MsgBox("Are you sure you want to exit?" & vbNewLine & "All the clients will be put into sleep mode.", vbYesNo + vbQuestion + vbSystemModal, "Quit")
If msg = vbYes Then
Form3.Show
Cancel = True
Form1.Visible = False
Else
Cancel = True
End If
End Sub
Private Sub List1_Click()
On Error GoTo errhandler
Dim ClientFound As Boolean
DeviceIP = Mid(List1.Text, InStr(List1.Text, "-") + 1)
DeviceIP = LTrim(DeviceIP)
DeviceIPLabel.Caption = "Device IP: " & DeviceIP
Form2.Show
If Socket1.RemoteHostIP = DeviceIP Then
Socket1.SendData ("SERVER_REQUESTS_DATA")
ElseIf Socket2.RemoteHostIP = DeviceIP Then
Socket2.SendData ("SERVER_REQUESTS_DATA")
End If
Exit Sub
errhandler:
If Err.Number = 40006 Then
MsgBox "Socket error!" & vbNewLine & "The requested device might be offline.", vbCritical + vbSystemModal, "Socket error"
Unload Form2
End If
End Sub
Private Sub UpdateList_Timer()
On Error Resume Next
If List1.ListCount > 0 Then
If UpdateListStatus = 0 Then
TempList.Clear
Socket1.SendData ("RESPOND_MESSAGE")
Socket2.SendData ("RESPOND_MESSAGE")
UpdateListStatus = 1
UpdateList.Interval = 5000
ElseIf UpdateListStatus = 1 Then
List1.Clear
For x = 0 To TempList.ListCount
List1.AddItem (TempList.List(x))
Next x
For X2 = 0 To List1.ListCount
If List1.List(X2) = "" Then 'Check if we have any items that are nothing
List1.RemoveItem (X2)
End If
Next X2
Label1.Caption = "Connected clients: " & List1.ListCount
UpdateListStatus = 0
UpdateList.Interval = 10000
End If
End If
End Sub
Private Sub Socket1_DataArrival(ByVal bytesTotal As Long)
On Error Resume Next
Dim TempString As String
Dim TempString2 As String
Dim position As Integer
Socket1.GetData TempString, vbString
position = InStr(1, TempString, "DEVICE_NAME=")
If position > 0 Then 'It is a device name command from a client
TempString2 = Mid(TempString, InStr(TempString, "=") + 1)
List1.AddItem (TempString2 + " - " + Socket1.RemoteHostIP)
Label1.Caption = "Connected clients: " & List1.ListCount
TempString2 = ""
End If
position = 0
position = InStr(1, TempString, "DEVICE_NAME_REP=")
If position > 0 Then 'It is a device name command from a client
TempString2 = Mid(TempString, InStr(TempString, "=") + 1)
DeviceNameLabel.Caption = "Device name: " & TempString2
TempString2 = ""
End If
position = 0
position = InStr(1, TempString, "DEVICE_FIRMWARE=")
If position > 0 Then 'It is a device firmware command from a client
TempString2 = Mid(TempString, InStr(TempString, "=") + 1)
DeviceFirmwareLabel.Caption = "Firmware version: " & TempString2
Unload Form2 'Since this is the last piece we will be receiving we can close this window
TempString2 = ""
End If
position = 0
position = InStr(1, TempString, "DEVICE_OK=")
If position > 0 Then 'It is a device respond command from a client
TempString2 = Mid(TempString, InStr(TempString, "=") + 1)
TempList.AddItem (TempString2 + " - " + Socket1.RemoteHostIP)
Label1.Caption = "Connected clients: " & List1.ListCount
TempString2 = ""
End If
position = 0
position = InStr(1, TempString, "DEVICE_REBOOTING")
If position > 0 Then 'It is a device respond command from a client
Socket1.Close
TempString2 = ""
End If
Text1.Text = Text1.Text & TempString & vbNewLine
TempString = ""
position = 0
TempString2 = ""
End Sub
Private Sub Socket2_DataArrival(ByVal bytesTotal As Long)
On Error Resume Next
Dim TempString As String
Dim TempString2 As String
Dim position As Integer
Socket2.GetData TempString, vbString
position = InStr(1, TempString, "DEVICE_NAME=")
If position > 0 Then 'It is a device name command from a client
TempString2 = Mid(TempString, InStr(TempString, "=") + 1)
List1.AddItem (TempString2 + " - " + Socket2.RemoteHostIP)
Label1.Caption = "Connected clients: " & List1.ListCount
TempString2 = ""
End If
position = 0
position = InStr(1, TempString, "DEVICE_NAME_REP=")
If position > 0 Then 'It is a device name command from a client
TempString2 = Mid(TempString, InStr(TempString, "=") + 1)
DeviceNameLabel.Caption = "Device name: " & TempString2
TempString2 = ""
End If
position = 0
position = InStr(1, TempString, "DEVICE_FIRMWARE=")
If position > 0 Then 'It is a device firmware command from a client
TempString2 = Mid(TempString, InStr(TempString, "=") + 1)
DeviceFirmwareLabel.Caption = "Firmware version: " & TempString2
Unload Form2 'Since this is the last piece we will be receiving we can close this window
TempString2 = ""
End If
position = 0
position = InStr(1, TempString, "DEVICE_OK=")
If position > 0 Then 'It is a device respond command from a client
TempString2 = Mid(TempString, InStr(TempString, "=") + 1)
TempList.AddItem (TempString2 + " - " + Socket2.RemoteHostIP)
Label1.Caption = "Connected clients: " & List1.ListCount
TempString2 = ""
End If
position = 0
position = InStr(1, TempString, "DEVICE_REBOOTING")
If position > 0 Then 'It is a device respond command from a client
Socket2.Close
TempString2 = ""
End If
Text1.Text = Text1.Text & TempString & vbNewLine
TempString = ""
position = 0
TempString2 = ""
End Sub
Private Sub Socket1_ConnectionRequest(ByVal requestID As Long)
If Socket1.State <> sckClosed Then
Socket1.Close
' Accept the request with the requestID
' parameter.
Socket1.Accept requestID
End If
End Sub
Private Sub Socket2_ConnectionRequest(ByVal requestID As Long)
If Socket2.State <> sckClosed Then
Socket2.Close
Socket2.Accept requestID 'Allow the connection
End If
End Sub
`
【问题讨论】:
-
你是如何连接的? TCP ?如果是这样,您是否使用不同的端口?请发布一些代码。
-
抱歉,不小心按回车键,所以没有可用的代码:/ 哦,我使用 TCP,socket1 使用端口 2444,socket2 使用端口 2445