【发布时间】:2018-05-28 19:05:41
【问题描述】:
我正在尝试使用串行连接从我的 Mac 笔记本电脑连接到 Modbus 设备 (MR-SI4),该设备使用“安装”到 /dev/cu.SLAB_USBtoUART 的 USB RS485 转换器。
这是我的代码:
import logging
logging.basicConfig()
log = logging.getLogger()
log.setLevel(logging.DEBUG)
from pymodbus.constants import Endian
from pymodbus.constants import Defaults
from pymodbus.payload import BinaryPayloadDecoder
from pymodbus.client.sync import ModbusSerialClient as ModbusClient
from pymodbus.transaction import ModbusRtuFramer
# settings for USB-RS485 adapter
SERIAL = '/dev/cu.SLAB_USBtoUART'
BAUD = 19200
# set Modbus defaults
Defaults.UnitId = 1
Defaults.Retries = 5
client = ModbusClient(method='rtu', port=SERIAL, stopbits=1, bytesize=8, timeout=3, baudrate=BAUD, parity='E')
connection = client.connect()
print "Readout started"
#result = client.read_discrete_inputs(0)
#result = client.read_holding_registers(12,19)
result = client.read_input_registers(0,1)
print(result)
控制台的输出是:
$ sudo python test.py
Readout started
DEBUG:pymodbus.transaction:Running transaction 1
DEBUG:pymodbus.transaction:send: 0x1 0x4 0x0 0x0 0x0 0x1 0x31 0xca
DEBUG:pymodbus.client.sync:will sleep to wait for 3.5 char
DEBUG:pymodbus.transaction:recv:
DEBUG:pymodbus.transaction:getting transaction 1
Modbus Error: [Input/Output] No Response received from the remote unit
我很想在理解我遇到的错误方面得到一点帮助。我尝试了pymodbus 的配置以及read_discrete_inputs 或read_holding_registers 等不同的功能。有什么帮助吗?
谢谢
【问题讨论】:
-
日志显示,远程单元没有为您的请求返回任何响应,如果您看到带有
DEBUG:pymodbus.transaction:recv:的行,那么在 3 秒的读取时间内您什么也得不到。我会说检查你的连接(接地)并仔细检查奇偶校验和波特率。
标签: python modbus pymodbus pymodbus3