【问题标题】:is there a way to read the data coming from a connected device within pymodbus?有没有办法读取来自 pymodbus 中连接设备的数据?
【发布时间】:2020-06-22 02:39:24
【问题描述】:

下面我有一个 pymodbus 的异步服务器作为例子

#!/usr/bin/env python
"""
Pymodbus Asynchronous Server Example
--------------------------------------------------------------------------

The asynchronous server is a high performance implementation using the
twisted library as its backend.  This allows it to scale to many thousands
of nodes which can be helpful for testing monitoring software.
"""
# --------------------------------------------------------------------------- # 
# import the various server implementations
# --------------------------------------------------------------------------- # 
from pymodbus.server.asynchronous import StartTcpServer
from pymodbus.server.asynchronous import StartUdpServer
from pymodbus.server.asynchronous import StartSerialServer

from pymodbus.device import ModbusDeviceIdentification
from pymodbus.datastore import ModbusSequentialDataBlock
from pymodbus.datastore import ModbusSlaveContext, ModbusServerContext
from pymodbus.transaction import (ModbusRtuFramer,
                                  ModbusAsciiFramer,
                                  ModbusBinaryFramer)
from custom_message import CustomModbusRequest

# --------------------------------------------------------------------------- # 
# configure the service logging
# --------------------------------------------------------------------------- # 
import logging
FORMAT = ('%(asctime)-15s %(threadName)-15s'
          ' %(levelname)-8s %(module)-15s:%(lineno)-8s %(message)s')
logging.basicConfig(format=FORMAT)
log = logging.getLogger()
log.setLevel(logging.DEBUG)


def run_async_server():
    # ----------------------------------------------------------------------- # 
    # initialize your data store
    # ----------------------------------------------------------------------- # 
    # The datastores only respond to the addresses that they are initialized to
    # Therefore, if you initialize a DataBlock to addresses from 0x00 to 0xFF,
    # a request to 0x100 will respond with an invalid address exception.
    # This is because many devices exhibit this kind of behavior (but not all)
    #
    #     block = ModbusSequentialDataBlock(0x00, [0]*0xff)
    #
    # Continuing, you can choose to use a sequential or a sparse DataBlock in
    # your data context.  The difference is that the sequential has no gaps in
    # the data while the sparse can. Once again, there are devices that exhibit
    # both forms of behavior::
    #
    #     block = ModbusSparseDataBlock({0x00: 0, 0x05: 1})
    #     block = ModbusSequentialDataBlock(0x00, [0]*5)
    #
    # Alternately, you can use the factory methods to initialize the DataBlocks
    # or simply do not pass them to have them initialized to 0x00 on the full
    # address range::
    #
    #     store = ModbusSlaveContext(di = ModbusSequentialDataBlock.create())
    #     store = ModbusSlaveContext()
    #
    # Finally, you are allowed to use the same DataBlock reference for every
    # table or you you may use a seperate DataBlock for each table.
    # This depends if you would like functions to be able to access and modify
    # the same data or not::
    #
    #     block = ModbusSequentialDataBlock(0x00, [0]*0xff)
    #     store = ModbusSlaveContext(di=block, co=block, hr=block, ir=block)
    #
    # The server then makes use of a server context that allows the server to
    # respond with different slave contexts for different unit ids. By default
    # it will return the same context for every unit id supplied (broadcast
    # mode).
    # However, this can be overloaded by setting the single flag to False
    # and then supplying a dictionary of unit id to context mapping::
    #
    #     slaves  = {
    #         0x01: ModbusSlaveContext(...),
    #         0x02: ModbusSlaveContext(...),
    #         0x03: ModbusSlaveContext(...),
    #     }
    #     context = ModbusServerContext(slaves=slaves, single=False)
    #
    # The slave context can also be initialized in zero_mode which means that a
    # request to address(0-7) will map to the address (0-7). The default is
    # False which is based on section 4.4 of the specification, so address(0-7)
    # will map to (1-8)::
    #
    #     store = ModbusSlaveContext(..., zero_mode=True)
    # ----------------------------------------------------------------------- # 
    store = ModbusSlaveContext(
        di=ModbusSequentialDataBlock(0, [17]*100),
        co=ModbusSequentialDataBlock(0, [17]*100),
        hr=ModbusSequentialDataBlock(0, [17]*100),
        ir=ModbusSequentialDataBlock(0, [17]*100))
    store.register(CustomModbusRequest.function_code, 'cm',
                   ModbusSequentialDataBlock(0, [17] * 100))
    context = ModbusServerContext(slaves=store, single=True)

    # ----------------------------------------------------------------------- # 
    # initialize the server information
    # ----------------------------------------------------------------------- # 
    # If you don't set this or any fields, they are defaulted to empty strings.
    # ----------------------------------------------------------------------- # 
    identity = ModbusDeviceIdentification()
    identity.VendorName = 'Pymodbus'
    identity.ProductCode = 'PM'
    identity.VendorUrl = 'http://github.com/bashwork/pymodbus/'
    identity.ProductName = 'Pymodbus Server'
    identity.ModelName = 'Pymodbus Server'
    identity.MajorMinorRevision = '2.3.0'

    # ----------------------------------------------------------------------- # 
    # run the server you want
    # ----------------------------------------------------------------------- # 

    # TCP Server

    StartTcpServer(context, identity=identity, address=("localhost", 5020),
                   custom_functions=[CustomModbusRequest])

    # TCP Server with deferred reactor run

    # from twisted.internet import reactor
    # StartTcpServer(context, identity=identity, address=("localhost", 5020),
    #                defer_reactor_run=True)
    # reactor.run()

    # Server with RTU framer
    # StartTcpServer(context, identity=identity, address=("localhost", 5020),
    #                framer=ModbusRtuFramer)

    # UDP Server
    # StartUdpServer(context, identity=identity, address=("127.0.0.1", 5020))

    # RTU Server
    # StartSerialServer(context, identity=identity,
    #                   port='/dev/ttyp0', framer=ModbusRtuFramer)

    # ASCII Server
    # StartSerialServer(context, identity=identity,
    #                   port='/dev/ttyp0', framer=ModbusAsciiFramer)

    # Binary Server
    # StartSerialServer(context, identity=identity,
    #                   port='/dev/ttyp0', framer=ModbusBinaryFramer)


if __name__ == "__main__":
    run_async_server()

这是连接设备中的命令,假设将数据传递到服务器

例如

modbusrtu -m tcp -a 1 -r 2 -p 502 192.168.1.2 1

上面的 modbusrtu 命令假设通过 tcp 端口 502 向位于服务器中地址为 192.168.1.2 的 modbus 寄存器地址 2 发送值 1

那么我想如何在我粘贴的那个 python 代码中获取数据数据? 比如在那个 pymodbus 服务器代码中,我想捕获寄存器地址 2 及其值 1 并将它们存储在一个变量中以供以后使用

【问题讨论】:

  • modbusrtu你写的自定义程序吗?如果它可以更新寄存器值,它还应该提供一种读取值的机制(理想情况下)

标签: python python-3.x pymodbus


【解决方案1】:

有几种方法,但您可以使用的一种方法是从您创建的ModbusSlaveContext 中删除值。例如,您可能可以执行store.store['h'].getValues(0, 1) 之类的操作来读取地址 0 处的保持寄存器的前 8 位。如果您想要一整行,请读取 2。然后你可以随意解码。

【讨论】: