【问题标题】:[AnyDac][DApt]-400 But my tables does have a PK[AnyDac][DApt]-400 但是我的桌子确实有 PK
【发布时间】:2013-02-26 07:02:01
【问题描述】:

[anydac][DApt]-400.Fetch 命令获取 [0] 而不是 [1] 记录, 可能原因:更新表没有PK或行标识符,记录已被其他用户更改/删除,

执行时

SingleTestRunADQuery.Append();
SingleTestRunADQuery.FieldByName('run_id').Value := StartRecordingButton.Tag;
SingleTestRunADQuery.FieldByName('ph_value').Value := FloatToStr(ph_reading);
SingleTestRunADQuery.FieldByName('conductivity_value').Value := conductivity_reading;
SingleTestRunADQuery.FieldByName('cod_value').Value := cod_reading;
SingleTestRunADQuery.Post();

开

mysql> describe measurements;
+------------------------+-----------+------+-----+-------------------+-------+
| Field                  | Type      | Null | Key | Default           | Extra |
+------------------------+-----------+------+-----+-------------------+-------+
| run_id                 | int(11)   | NO   | MUL | NULL              |       |
| measurement_time_stamp | timestamp | NO   | PRI | CURRENT_TIMESTAMP |       |
| ph                     | float     | NO   |     | NULL              |       |
| conductivity           | float     | NO   |     | NULL              |       |
| cod                    | float     | NO   |     | NULL              |       |
+------------------------+-----------+------+-----+-------------------+-------+
5 rows in set (0.03 sec)

如您所见,该表确实有一个 PK。另外,程序是单线程的,只有一个副本在运行,所以没有其他人在更新。

我设置了SingleTestRunADQuery.MasterFields=run_id and IndexFieldNames=run_id,因为它是包含所有测试运行摘要的表的 PK。第二张表包含测试期间进行的测量,run_id 提供了一次测试运行的所有测量值(我只在 tiemstamp 上添加了 PK 以消除此错误,但它不起作用并且可以删除,我猜) .

如果有帮助,这里是主数据源:

mysql> describe test_runs;
+------------------+-------------+------+-----+-------------------+----------------+
| Field            | Type        | Null | Key | Default           | Extra          |
+------------------+-------------+------+-----+-------------------+----------------+
| run_id           | int(11)     | NO   | PRI | NULL              | auto_increment |
| start_time_stamp | timestamp   | NO   |     | CURRENT_TIMESTAMP |                |
| end_time_stamp   | timestamp   | YES  |     | NULL              |                |
| description      | varchar(64) | YES  |     | NULL              |                |
+------------------+-------------+------+-----+-------------------+----------------+
4 rows in set (0.05 sec)

知道有什么问题吗?


[更新]@mj2008 指出某些字段有不同的名称。这是出于历史原因(我仍在尝试一些东西并且还不想改变),但是这些是由查询调整的:

SELECT run_id,
       measurement_time_stamp, 
       ph as ph_value, 
       conductivity as conductivity_value, 
       cod as cod_value

FROM photo_catalytic.measurements

ORDER BY measurement_time_stamp DESC

【问题讨论】:

  • 代码中的字段名称与表输出不匹配。修复它,然后告诉我们它是否仍然失败。
  • oic,是的,但是由于历史原因,查询关联了这些名称,例如 SELECT ph AS ph_value。会不会是这个原因?
  • "conductivity_value" 和 "conductivity" 对于初学者来说。

标签: delphi master-detail anydac


【解决方案1】:

我不确定将 TIMESTAMP 字段作为主键是否正确。每次更新都会automatically change。

【讨论】:

  • 同意 事实上,该表没有 PK - 我认为不需要,但当错误消息似乎需要它时,我添加了它。我以前没有它并且犯了同样的错误。有趣的是,当我只想插入时,AnyDac 正在创建某种 Fetch。在第一次插入时,没有任何东西可以获取
  • 顺便说一句,我永远不会UPDATE 测量(详细信息表),只运行测试(主表)。
【解决方案2】:

通过“字段编辑器”选项查看查询组件的 TFields 属性。检查“关键字段”是否将 ProviderFlags.pfInKey 属性设置为 true。

这适用于今天的 FireDac 组件。

【讨论】:

    【解决方案3】:

    您应该按如下方式更改连接属性:尝试将 UpdateOptions.RefreshMode 设置为 rmManual。

    enter image description here

    【讨论】:

    • 正如目前所写,您的答案尚不清楚。请edit 添加其他详细信息,以帮助其他人了解这如何解决所提出的问题。你可以找到更多关于如何写好答案的信息in the help center。