【问题标题】:How can I get the PID of the parent process of my application如何获取应用程序父进程的 PID
【发布时间】:2011-02-01 16:12:57
【问题描述】:

我的 winform 应用程序由另一个应用程序(父应用程序)启动,我需要确定使用 C# 启动我的应用程序的应用程序的 pid。

【问题讨论】:

标签: c# .net winforms process pid


【解决方案1】:

使用 Brian R. Bondy 的回答作为指导,以及 PInvoke.net 上的内容和一些 Reflector 输出,我制作了这个,用于 LinqPad MyExtensions

using Microsoft.Win32.SafeHandles;
using System;
using System.ComponentModel;
using System.Diagnostics;
using System.Runtime.ConstrainedExecution;
using System.Runtime.InteropServices;
using System.Security;
using System.Security.Permissions;

static class ProcessExtensions
{
    public static int ParentProcessId(this Process process)
    {
      return ParentProcessId(process.Id);
    }
    public static int ParentProcessId(int Id)
    {
        PROCESSENTRY32 pe32 = new PROCESSENTRY32{};
        pe32.dwSize = (uint)Marshal.SizeOf(typeof(PROCESSENTRY32));
        using(var hSnapshot = CreateToolhelp32Snapshot(SnapshotFlags.Process, (uint)Id))
        {
            if(hSnapshot.IsInvalid)
                throw new Win32Exception();

            if(!Process32First(hSnapshot, ref pe32))
            {
                int errno = Marshal.GetLastWin32Error();
                if(errno == ERROR_NO_MORE_FILES)
                    return -1;
                throw new Win32Exception(errno);
            }    
            do {
                    if(pe32.th32ProcessID == (uint)Id)
                        return (int)pe32.th32ParentProcessID;
            } while(Process32Next(hSnapshot, ref pe32));
        }
        return -1;
    }
    private const int ERROR_NO_MORE_FILES = 0x12;
    [DllImport("kernel32.dll", SetLastError=true)]
    private static extern SafeSnapshotHandle CreateToolhelp32Snapshot(SnapshotFlags flags, uint id);
    [DllImport("kernel32.dll", SetLastError=true)]
    private static extern bool Process32First(SafeSnapshotHandle hSnapshot, ref PROCESSENTRY32 lppe);
    [DllImport("kernel32.dll", SetLastError=true)]
    private static extern bool Process32Next(SafeSnapshotHandle hSnapshot, ref PROCESSENTRY32 lppe);

    [Flags]
    private enum SnapshotFlags : uint
    {
        HeapList = 0x00000001,
        Process  = 0x00000002,
        Thread   = 0x00000004,
        Module   = 0x00000008,
        Module32 = 0x00000010,
        All      = (HeapList | Process | Thread | Module),
        Inherit  = 0x80000000,
        NoHeaps  = 0x40000000
    }
    [StructLayout(LayoutKind.Sequential)]
    private struct PROCESSENTRY32 
    { 
      public uint dwSize; 
      public uint cntUsage; 
      public uint th32ProcessID; 
      public IntPtr th32DefaultHeapID; 
      public uint th32ModuleID; 
      public uint cntThreads; 
      public uint th32ParentProcessID; 
      public int pcPriClassBase; 
      public uint dwFlags; 
      [MarshalAs(UnmanagedType.ByValTStr, SizeConst=260)] public string szExeFile; 
    };
    [SuppressUnmanagedCodeSecurity, HostProtection(SecurityAction.LinkDemand, MayLeakOnAbort=true)]
    internal sealed class SafeSnapshotHandle : SafeHandleMinusOneIsInvalid
    {
        internal SafeSnapshotHandle() : base(true)
        {
        }

        [SecurityPermission(SecurityAction.LinkDemand, UnmanagedCode=true)]
        internal SafeSnapshotHandle(IntPtr handle) : base(true)
        {
            base.SetHandle(handle);
        }

        protected override bool ReleaseHandle()
        {
            return CloseHandle(base.handle);
        }

        [ReliabilityContract(Consistency.WillNotCorruptState, Cer.Success), DllImport("kernel32.dll", CharSet=CharSet.Auto, SetLastError=true, ExactSpelling=true)]
        private static extern bool CloseHandle(IntPtr handle);
    }
}

【讨论】:

    【解决方案2】:

    WMI 是在 C# 中执行此操作的更简单方法。 Win32_Process 类具有 ParentProcessId 属性。这是一个例子:

    using System;
    using System.Management;  // <=== Add Reference required!!
    using System.Diagnostics;
    
    class Program {
        public static void Main() {
            var myId = Process.GetCurrentProcess().Id;
            var query = string.Format("SELECT ParentProcessId FROM Win32_Process WHERE ProcessId = {0}", myId);
            var search = new ManagementObjectSearcher("root\\CIMV2", query);
            var results = search.Get().GetEnumerator();
            results.MoveNext();
            var queryObj = results.Current;
            var parentId = (uint)queryObj["ParentProcessId"];
            var parent = Process.GetProcessById((int)parentId);
            Console.WriteLine("I was started by {0}", parent.ProcessName);
            Console.ReadLine();
        }
    }
    

    从 Visual Studio 运行时的输出:

    我是由 devenv 启动的

    【讨论】:

      【解决方案3】:

      如果您可以控制父应用程序,则可以修改父应用程序以在子进程启动时将其 PID 传递给子进程。

      【讨论】:

      • 简洁至上。这就是我一直在寻找的答案。
      【解决方案4】:

      检查 CreateToolhelp32Snapshot 枚举的 th32ParentProcessID 成员。

      有关如何执行此操作的示例see my post here

      由于您使用的是 C#,但您需要使用 DllImports。在链接的帖子中,每个都有您需要的功能的 MSDN 页面。在每个 MSDN 页面的底部,它们都有用于 C# 的 DllImport 的代码。

      还有一个 easier way using managed 代码,但如果您有多个由不同应用程序启动的进程名称,则它不起作用。

      【讨论】:

        猜你喜欢
        • 2010-09-16
        • 2014-12-11
        • 2014-06-25
        • 2015-01-05
        • 2016-02-01
        • 2015-10-25
        • 2010-09-05
        • 2012-05-21
        • 2014-05-12
        相关资源
        最近更新 更多