【问题标题】:DllNotFoundException in ClickOnce applicationClickOnce 应用程序中的 DllNotFoundException
【发布时间】:2017-03-13 11:26:30
【问题描述】:

我的 WPF 应用程序运行良好,但是当我将其部署为 ClickOnce 应用程序时,它甚至无法启动。但是在 Windows 事件查看器中引发了以下异常:

Application: Saito ERC-C.exe
Framework Version: v4.0.30319
Description: The process was terminated due to an unhandled exception.
Exception Info: System.DllNotFoundException
   at System.Data.SQLite.UnsafeNativeMethods.sqlite3_config_none(System.Data.SQLite.SQLiteConfigOpsEnum)
   at System.Data.SQLite.SQLite3.StaticIsInitialized()
   at System.Data.SQLite.SQLiteLog.Initialize()
   at System.Data.SQLite.SQLiteConnection..ctor(System.String, Boolean)
   at System.Data.SQLite.SQLiteConnection..ctor(System.String)
   at Saito_ERC_C.helpers.DBHelper.executeQuery(System.String)
   at Saito_ERC_C.LoginWindow..ctor()

Exception Info: System.Windows.Markup.XamlParseException
   at System.Windows.Markup.WpfXamlLoader.Load(System.Xaml.XamlReader, System.Xaml.IXamlObjectWriterFactory, Boolean, System.Object, System.Xaml.XamlObjectWriterSettings, System.Uri)
   at System.Windows.Markup.WpfXamlLoader.LoadBaml(System.Xaml.XamlReader, Boolean, System.Object, System.Xaml.Permissions.XamlAccessLevel, System.Uri)
   at System.Windows.Markup.XamlReader.LoadBaml(System.IO.Stream, System.Windows.Markup.ParserContext, System.Object, Boolean)
   at System.Windows.Application.LoadBamlStreamWithSyncInfo(System.IO.Stream, System.Windows.Markup.ParserContext)
   at System.Windows.Application.LoadComponent(System.Uri, Boolean)
   at System.Windows.Application.DoStartup()
   at System.Windows.Application.<.ctor>b__1_0(System.Object)
   at System.Windows.Threading.ExceptionWrapper.InternalRealCall(System.Delegate, System.Object, Int32)
   at System.Windows.Threading.ExceptionWrapper.TryCatchWhen(System.Object, System.Delegate, System.Object, Int32, System.Delegate)
   at System.Windows.Threading.DispatcherOperation.InvokeImpl()
   at System.Windows.Threading.DispatcherOperation.InvokeInSecurityContext(System.Object)
   at System.Threading.ExecutionContext.RunInternal(System.Threading.ExecutionContext, System.Threading.ContextCallback, System.Object, Boolean)
   at System.Threading.ExecutionContext.Run(System.Threading.ExecutionContext, System.Threading.ContextCallback, System.Object, Boolean)
   at System.Threading.ExecutionContext.Run(System.Threading.ExecutionContext, System.Threading.ContextCallback, System.Object)
   at MS.Internal.CulturePreservingExecutionContext.Run(MS.Internal.CulturePreservingExecutionContext, System.Threading.ContextCallback, System.Object)
   at System.Windows.Threading.DispatcherOperation.Invoke()
   at System.Windows.Threading.Dispatcher.ProcessQueue()
   at System.Windows.Threading.Dispatcher.WndProcHook(IntPtr, Int32, IntPtr, IntPtr, Boolean ByRef)
   at MS.Win32.HwndWrapper.WndProc(IntPtr, Int32, IntPtr, IntPtr, Boolean ByRef)
   at MS.Win32.HwndSubclass.DispatcherCallbackOperation(System.Object)
   at System.Windows.Threading.ExceptionWrapper.InternalRealCall(System.Delegate, System.Object, Int32)
   at System.Windows.Threading.ExceptionWrapper.TryCatchWhen(System.Object, System.Delegate, System.Object, Int32, System.Delegate)
   at System.Windows.Threading.Dispatcher.LegacyInvokeImpl(System.Windows.Threading.DispatcherPriority, System.TimeSpan, System.Delegate, System.Object, Int32)
   at MS.Win32.HwndSubclass.SubclassWndProc(IntPtr, Int32, IntPtr, IntPtr)
   at MS.Win32.UnsafeNativeMethods.DispatchMessage(System.Windows.Interop.MSG ByRef)
   at System.Windows.Threading.Dispatcher.PushFrameImpl(System.Windows.Threading.DispatcherFrame)
   at System.Windows.Threading.Dispatcher.PushFrame(System.Windows.Threading.DispatcherFrame)
   at System.Windows.Application.RunDispatcher(System.Object)
   at System.Windows.Application.RunInternal(System.Windows.Window)
   at System.Windows.Application.Run(System.Windows.Window)
   at Saito_ERC_C.App.Main()

我认为可能缺少一些 sqlite dll,所以我以这种方式修改了应用程序文件,但没有成功。

我应该如何解决这个问题?

【问题讨论】:

    标签: c# wpf sqlite clickonce


    【解决方案1】:

    经过数小时的尝试,我找到了解决方案。 (see )

    在我的项目根目录中创建了名为 x64、x86 的文件夹,然后分别从 bin\Release\x64 和 bin\Release\x64 文件夹中添加了 SQLite.Interop.dll 文件。

    然后它在部署后工作。

    【讨论】:

      猜你喜欢
      • 1970-01-01
      • 2012-02-03
      • 1970-01-01
      • 2017-09-18
      • 1970-01-01
      • 1970-01-01
      • 1970-01-01
      • 1970-01-01
      • 1970-01-01
      相关资源
      最近更新 更多